(1) Reasonable design
(2) Easy Installation
(3) Resistive Lithium Chloride Material
(4) Strict Inspection
(5) Widely Used in Power Generator set canopy, engine water tank and other machine.
Material | Resistive Lithium Chloride |
Voltage | 24V |
Temperature | -25ºC ~ + 125ºC |
Range | 0 ~ 1.0 Mpa |
Alarm Pressure | 0.08 ±0.02 Mpa |
Value of resistance | 0 to 1.0 Mpa |
Technical Specification
Oil Pressure | 0 | 0.2 | 0.4 | 0.6 | 0.8 | 1 |
Resistance Ω | 10±2 | 52±8 | 88±4 | 124±5 | 155±5 | 187±10 |