oil filled pressure gauge
1. The shell and internal components of the oil filled pressure gauge are made of stainless steel, and the body is filled with silicone oil, so that the pointer of the pressure gauge can play the role of shock absorption and earthquake resistance.
2. The oil filled pressure gauge not only has the shock resistance of the shock resistant pressure gauge, but also has the corrosion resistance of the stainless steel pressure gauge. The stainless steel oil filled pressure gauge is suitable for the occasions with large vibration in the industrial and mining sites and corrosive medium in the amount of sediment.
3. It is mainly used for pressure phase measurement in metallurgy, electric power, petroleum, chemical industry, light industry, machinery and other departments. The pressure gauge relies on measures such as filling damping oil internally and configuring buffer device. It has good shock resistance. Pressure applicable to the measured medium places with strong pulse change or pressure impact, as well as places where unloading is often prominent in the production process, and places with large environmental vibration. The instrument can measure the average value of fluctuating pressure of gas and liquid, so as to overcome the damage to the instrument caused by strong medium pulse and environmental vibration, and ensure the accuracy of reading. The shell of the stainless steel shock proof pressure gauge is made of stainless steel, which can be used in the harsh environment with non-staple food and large vibration.
The charge pressure gauge has the following features:
1. it has good shock resistance and can withstand the instantaneous pressure impact within the measurement range.
2.with good damping characteristics, it can measure the instantaneous average pressure of pulsating medium.
3. excellent anti blocking performance, strong adaptability to complex media such as high viscosity, easy to crystallize, containing granular and fibrous substances and oil stains.
4. the instrument adopts a fully sealed structure, which can work in high humidity, dust, splash and shallow water.
5. all metal shell and devices are solid and reliable.
6. beautiful appearance and clear dial.
Precautions for use of oil charging pressure gauge:
1. The instrument must be vertical: a 17mm wrench shall be used to tighten the instrument during installation. The case shall not be forced to twist. Collision shall be avoided during transportation.
2. The instrument should be used at the ambient temperature of -25~55 ℃.
3. The working environment vibration frequency is <25hz, and the amplitude is not greater than 1mm.
4. The upper part of the case can be sealed in case that the indicated value of the instrument does not return to zero or the indicated value exceeds the tolerance due to high ambient temperature during use.
5. Cut the rubber plug to make the instrument cavity open to the atmosphere.
6. The application range of the instrument shall be between 1/3 and 2/3 of the upper limit.
7. Isolation device shall be added for measuring corrosive medium, medium that may crystallize and medium with high viscosity.
8. The instrument shall be verified frequently (at least once every three months). If any fault is found, it shall be repaired in time.